The Convenient Vital Sign Monitor E8

Features of Huan Vital Sign Monitor E8:

  • Standard Parameters: SpO2, PR, NIBP
  • Optional Parameters: Nellcor SpO2, Suntech NIBP, Infrared TEMP.
  • Smart, Stable, Portable
    • Combining together a ultra-slim design with 8inch TFT OLD display . E8 is a new generation of specialized transferring patients .It is designed according to the transportation monitoring requirements for practicability, convenience and reliability of emergency treatment, first aid and transportation.The accurate measurement makes the Neonates monitoring safer, more stable and more convenient.
  • WIFI with smart IT solutions
    • Wireless integration with Central Monitoring Station
    • Dynamic trends provide up to 240 hours of useful information for review
    • 8 traces per monitor and 16 monitors on one screen
    • View up to 64 maximum bed on one plateform in real-time
    • Review and manage patient data anytime and anywhere in and pre-hospital

1 review for The Convenient Vital Sign Monitor E8

  1. Rated 5 out of 5

    Huan Instrument (store manager)

    It’s Awesome! Check it out!

Add a review

Your email address will not be published. Required fields are marked *

Quality Standards and Classification CE, ISO13485

  • SFDA: Class Ⅱb
  • Anti-electroshock degree: ClassⅠequipment (internal power supply), SpO 2 /NIBP: BF

Application Range

  • Adult/Pediatric/Neonatal/Medicine/Surgery

Display

  • 8” real color TFT screen
  • Resolution:800*600
  • One alarm indicator
  • One working indicator
  • One battery charge state indicator

Operating Environment

  • Temperature: 0-40 C
  • Humidity: 15%-80%
  • Pressure: 86.0 kPa- 106.0kPa
  • Transport and Storage environment
  • Temperature:-20-55 C
  • Humidity: 10%~90%
  • Pressure: 86.0 kPa-106.0kPa

Power Requirements

  • AC:100~240V,50Hz/60Hz
  • DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion battery
  • 2h operating after full charge
  • 5min operating after low battery alarm

Dimension and Weight

  • 164.2mm x 270.2mm x128.7 mm(about) 2.5kg(about)
  • Package: 360*250*290mm 4kg(about)

Data Strorage

  • Trend diagram/table: 720h
  • NIBP review: 1000 groups
  • Wave review: 12h
  • Alarm Review: 200 alarm events

NIBP

  • Method Oscillometry
  • Measure mode: Manual Auto, STAT
  • Measure interval in auto mode: 1-5/10115/3060/90/120/180/240/480m
  • Measure period in STAT mode: 5min
  • Pulse rate range: 40- 240bpm
  • Measure &alarm range:
    • Adult
      • SYS 40-280mmHg
      • DIA 10~220mmHg
      • MEAN 20-240mmHg
    • Pediatric
      • SYS 40~220mmHg
      • DIA 10-160mmHg
      • MEAN 20- 170mmHg
    • Neonatal
      • SYS 40~135mmHg
      • DIA 10- 100mmHg
      • MEAN 20-110mmHg
  • Static pressure measurement Range: 0 -300mmHg
  • Accuracy: ±3mmHg
  • Resolution: 1mmHg Accuracy
  • Max Mean Error: ± 5mmHg
  • Max Standard Deviation: 8mmHg Overpressure protection
    • Adult 300mmHg
    • Pediatric 240mmHg
    • Neonatal 150mmHg

SpO2

  • Measurement range: 0-100%Resolution
  • Accuracy: 70%~100% ±2%; 40%~69% ±3%

Pulse Rate

  • Measure/alarm range: 20- 300bpm Resolution:1bpm
  • Accuracy:±3bpm