Features of Respiratory High-Flow Therapy Device H-80 Series
- Respiratory High-Flow Therapy Device H-80 Series can be used for patients with spontaneous breathing, including artificial airway respiratory insufficiency, and can be used for patients in hospitals and long-term care institutions highly integrated design, to meet more needs of clinical treatment
- In high flow mode, flow rate is 2 L / min – 80 L / min, which can set the concentration of inhaled oxygen automatically.
- Provide a maximum of SOL/ min air/oxygen mixed gases, oxygen concentration can be set automatically, providing Auto Flow function, Smartflow function
- Disinfection-free design, water chamber has a backflow prevention valve to prevent gas backflow, and overall maintenance is more convenient
- Control target oxygen concentration automatically, oxygen delivery in the machine, 21% -100%, accurate to 1%; Wall oxygen source, oxygen cylinder, oxygen generator can support it; The built-in ultrasonic oxygen sensor requires no maintenance
- 9-stage humidification temperature: 29℃ -37℃, accurate to 1℃.
- Advanced dual fan design, two levels of HFlow and LFlow, 2 L / min – 80 L / min, can meet patients of most ages
Innovative 7-level humidity compensation function, providing ± 3 adjustable humidity compensation, easily coping with various harsh temperature and humidity environments - Automatically set the output flow parameters based on the peak expiratory flow (PEF) of the patient, simplifying the setting steps, satisfying the treatment effect and improving patient comfort
- Follow the patient’s every breath, switch the flow between breaths, provide a higher flow when inhaling, and a lower flow when exhaling, follow your every breath like a bi-level ventilator, comfortable and more economical oxygen resources.
- Respiratory High-Flow Therapy Device H-80 Series has a warm standby function, which allows you to continue warm oxygen therapy at any time without turning off the machine for a short time to leave, saving oxygen without having to wait for warm-up time
- Real-time monitoring of Oxygen Concentration, Flow, Temperature, Respiratory Rate, sPEEP
- Integration, disinfection-free design, saving clinical use and maintenance time
Details
Respiratory High-Flow Therapy Device H-80 Series
| H-80AS | H-80A | H-80M | |
|---|---|---|---|
| Adjustment method of oxygen concentration | Auto | Auto | Manual |
| Flow | Monitorable, adjustable | Monitorable, adjustable during oxygen delivery | Monitorable, adjustable |
| Flow range | 2L-80L/min | 2L-80L/min | 2L-80L/min |
| Oxygen concentration adjustment range | 21-100% | 21-100% | 21-100% |
| *Temperature output range | 29-37℃ | 29-37℃ | 29-37℃ |
| *Temperature adjustment gear | 9 steps adjustable | 9 steps adjustable | 9 steps adjustable |
| Disinfection-free | Yes | Yes | Yes |
| conception | 3.5 inches | 3.5 inches | 3.5 inches |
| Screen size | 1 day; 3 days; 7 days | 1 day; 3 days; 7 days | 1 day; 3 days; 7 days |
| Trend review function | Monitorable, adjustable | Monitorable, adjustable | Monitorable |
| Oxygen concentration Temperature | Monitorable, adjustable | Monitorable, adjustable | Monitorable, adjustable |
| *sPEEP | Monitorable | Monitorable | Monitorable |
| *Respiratory rate | Monitorable | Monitorable | Monitorable |
| Automatic reminder of filter replacement | Yes, settable | Yes, settable | Yes, settable |
| Automatic water filling function | Yes | Yes | Yes |
| *AutoFlow | Yes | / | / |
| *SmartFlow | Yes | / | / |
| Humidity compensation | -3-+3, 7 steps adjustable | -3-+3, 7 steps adjustable | -3-+3, 7 steps adjustable |
| *sPEEP set | 0-4 steps adjustable | / | / |
| *Warm standby | Yes | Yes | Yes |